general mechanical troubleshooting

All electrical work must be performed by a certified electrician


Before proceeding with troubleshooting, check the following:


  • Water level (must be at least 3” above skimmer opening)
  • Filters have been cleaned with a proper filter clean solution within the last 3 weeks.
  • Turn off GFI, wait 2 minutes and then turn it back on


K.I.S (Keep it simple) – Check the easiest solutions first


Symptom: No Heat (Tub not going to set temp.)
Pull filter (see if light comes on), if so... Replace filter
Knife valves not fully open, if so... Open knife valves
Pressure switch out of calibration, if so... Adjust pressure switch
Faulty Pressure Switch, if so... Replace pressure switch
Air leak, check pump suction line, if so... Tighten pump union
Heating element corroded, if so... Replace element
Faulty control panel, if so... Replace panel

Symptom: ‘FLO’ Error message
Pressure switch out of calibration, if so... Adjust pressure switch
Faulty pressure switch, if so... Replace pressure switch

Symptom: Poor jet pressure / No air to jets
Individual jets off, if so... Turn on (counterclockwise)
Individual jets not tight in housing, if so... Ensure all jets are tight
Knife valves not fully open, if so... Open knife valves
Air leak check pump suction line, if so... Tighten pump union
Check all jet o-rings, if so... Replace damaged o-rings
Impeller separated from shaft, if so... Replace impeller & re seal

Symptom: Tub water too hot / High limit tripped / OH or SN
Temperature sensor not bottomed out in well, if so... Push sensor in further
Tub water too hot from ambient heat of pump, if so... Shorten filter cycles
Faulty circuit board, if so... Replace board
Faulty control panel, if so... Replace panel
Faulty sensor, if so... Replace sensor set

Symptom: GFI tripping
Improper installation, size wire, or GFI, if so... Rewire to electrical specs
Wet equipment (Ozone), if so... Dry equipment
Ground fault in heater (dry operation or corrosion), if so... Replace element
Faulty GFI, if so... Electrician to replace GFI

Symptom: Functions not working
Reset GFI... GFI–off-wait 10 min. –on
Panel is locked, if so... Unlock panel
Faulty control panel, if so... Replace panel
Faulty circuit board, if so... Replace board

Symptom: Temperature fluctuating (More than 2-3 F)
Sensor well exposed, if so... Insulate well
Faulty sensors, if so... Replace sensor set

Symptom: Individual jets wont turn off
Jets sticky / dry, if so... Clean & relubricate Debris jammed inside of jet, if so... Clean internal

Symptom: Pump not operating correctly
Air lock on start up, if so... Purge air out of pump
Purge valve open, if so... Close purge valve
Pump suctions plugged, if so... Clean suction
Burnt out fuse, if so... Replace fuse
Pump thermal over load, if so... Require better venting
Hi-Lo reversed, if so... Reverse Hi-Lo wires on pump
Pump cord, if so... Replace cord
Faulty pump, if so... Replace pump
Faulty control panel, if so... Replace panel

Symptom: No digital read out
Control panel unplugged or loose, if so... Plug in panel
Burnt out fuse, if so... Replace fuse
Faulty control panel, if so... Replace panel
Faulty circuit board, if so... Replace board

Symptom: Light doesn’t turn off / on
Faulty bulb, if so... Replace bulb
Faulty control panel, if so... Replace panel
Faulty circuit board, if so... Replace board

Symptom: Ozone / UV not working
Debris in impeller, if so... Clean impeller
UV bulb / ozone chip burnt out, if so... Replace bulb

Symptom: Water loss or wet spot
Water level to high, if so... Lower water level
Jet not tight in housing, if so... Check and tighten all jets
Loose plumbing connection, if so... Tighten unions
Faulty pump seal, if so... Re-seal pump

Symptom: Tub making strange noises
Water level to high, if so... Lower water level
Jet not tight in housing, if so... Check and tighten all jets
Loose plumbing connection, if so... Tighten unions
Faulty pump seal, if so... Re-seal pump

Symptom: Cover seams coming apart
PH too low – Acidic water, if so... Raise PH to 7.5
Sanitizer too high – Corrosive, if so... Lower sanitation level
Cover lifter on center seam, if so... Reinforce center seam
Cover is a water logged, if so... Replace foam insert

Symptom: Pillows/filter cover fading
PH too low – Acidic water, if so... Raise PH to 7.5
Sanitizer too high – corrosive, if so... Lower sanitation level


To learn more check out our downloads on the main page.
            

Eric from Eric's World of leisure, Prince George, BC,  repairing a hot tub.

Prince George, BC repair by Eric's World

5 Common HOT TUB PROBLEMS and Solutions

 On this episode Swim University is talking about some common problems you might have with your hot tub and how to troubleshoot them. 

Copyright © 2024 Canadian Hot Tub Retailers - All Rights Reserved.

  • Privacy Policy
  • Acrylic Repair
  • Delivery Access
  • Site Selection
  • Site Preparation
  • Electrical Connection
  • General Troubleshooting
  • Centrex Repair
  • Winterizing
  • Spa Maintenance
  • Alberta
  • British Columbia
  • Manitoba
  • NW & Yukon Territory
  • New Brunswick
  • Newfoundland & Labrador
  • Nova Scotia
  • Nunavut
  • Ontario
  • Prince Edward Island
  • Quebec
  • Saskatchewan
  • Air Controls
  • Carbon Block Filters
  • Filtration
  • Fittings
  • Glue and Primer
  • Jets - Troubleshooting
  • Pumps – General
  • Pump Shaft Seals
  • Spa Pump Exploded View
  • Standard Components
  • Valves
  • Water Diverters
  • Water Fountains
  • Waterfalls
  • Water Manifolds
  • Spa Lighting
  • What is a Blower
  • Basic Chemical Safety
  • Start up chemicals
  • Chemical Maintenance
  • What is ozone
  • What are salt systems
  • What is UV

Powered by GoDaddy Website Builder