All electrical work must be performed by a certified electrician
Before proceeding with troubleshooting, check the following:
K.I.S (Keep it simple) – Check the easiest solutions first
Symptom: No Heat (Tub not going to set temp.)
Pull filter (see if light comes on), if so... Replace filter
Knife valves not fully open, if so... Open knife valves
Pressure switch out of calibration, if so... Adjust pressure switch
Faulty Pressure Switch, if so... Replace pressure switch
Air leak, check pump suction line, if so... Tighten pump union
Heating element corroded, if so... Replace element
Faulty control panel, if so... Replace panel
Symptom: ‘FLO’ Error message
Pressure switch out of calibration, if so... Adjust pressure switch
Faulty pressure switch, if so... Replace pressure switch
Symptom: Poor jet pressure / No air to jets
Individual jets off, if so... Turn on (counterclockwise)
Individual jets not tight in housing, if so... Ensure all jets are tight
Knife valves not fully open, if so... Open knife valves
Air leak check pump suction line, if so... Tighten pump union
Check all jet o-rings, if so... Replace damaged o-rings
Impeller separated from shaft, if so... Replace impeller & re seal
Symptom: Tub water too hot / High limit tripped / OH or SN
Temperature sensor not bottomed out in well, if so... Push sensor in further
Tub water too hot from ambient heat of pump, if so... Shorten filter cycles
Faulty circuit board, if so... Replace board
Faulty control panel, if so... Replace panel
Faulty sensor, if so... Replace sensor set
Symptom: GFI tripping
Improper installation, size wire, or GFI, if so... Rewire to electrical specs
Wet equipment (Ozone), if so... Dry equipment
Ground fault in heater (dry operation or corrosion), if so... Replace element
Faulty GFI, if so... Electrician to replace GFI
Symptom: Functions not working
Reset GFI... GFI–off-wait 10 min. –on
Panel is locked, if so... Unlock panel
Faulty control panel, if so... Replace panel
Faulty circuit board, if so... Replace board
Symptom: Temperature fluctuating (More than 2-3 F)
Sensor well exposed, if so... Insulate well
Faulty sensors, if so... Replace sensor set
Symptom: Individual jets wont turn off
Jets sticky / dry, if so... Clean & relubricate Debris jammed inside of jet, if so... Clean internal
Symptom: Pump not operating correctly
Air lock on start up, if so... Purge air out of pump
Purge valve open, if so... Close purge valve
Pump suctions plugged, if so... Clean suction
Burnt out fuse, if so... Replace fuse
Pump thermal over load, if so... Require better venting
Hi-Lo reversed, if so... Reverse Hi-Lo wires on pump
Pump cord, if so... Replace cord
Faulty pump, if so... Replace pump
Faulty control panel, if so... Replace panel
Symptom: No digital read out
Control panel unplugged or loose, if so... Plug in panel
Burnt out fuse, if so... Replace fuse
Faulty control panel, if so... Replace panel
Faulty circuit board, if so... Replace board
Symptom: Light doesn’t turn off / on
Faulty bulb, if so... Replace bulb
Faulty control panel, if so... Replace panel
Faulty circuit board, if so... Replace board
Symptom: Ozone / UV not working
Debris in impeller, if so... Clean impeller
UV bulb / ozone chip burnt out, if so... Replace bulb
Symptom: Water loss or wet spot
Water level to high, if so... Lower water level
Jet not tight in housing, if so... Check and tighten all jets
Loose plumbing connection, if so... Tighten unions
Faulty pump seal, if so... Re-seal pump
Symptom: Tub making strange noises
Water level to high, if so... Lower water level
Jet not tight in housing, if so... Check and tighten all jets
Loose plumbing connection, if so... Tighten unions
Faulty pump seal, if so... Re-seal pump
Symptom: Cover seams coming apart
PH too low – Acidic water, if so... Raise PH to 7.5
Sanitizer too high – Corrosive, if so... Lower sanitation level
Cover lifter on center seam, if so... Reinforce center seam
Cover is a water logged, if so... Replace foam insert
Symptom: Pillows/filter cover fading
PH too low – Acidic water, if so... Raise PH to 7.5
Sanitizer too high – corrosive, if so... Lower sanitation level
To learn more check out our downloads on the main page.